Product
  • Instrument Analytical instrument Biology instrument Healthcare instrument Histology instrument Hospital & Lab instrument Other instrument Consumable ESU pencil Histology Consumable Microtome blade holder Slides and Cover Glass Slides storage
  • Product details
    NameMH1800
    Detailed profile:

                                                                      User manual.pdf

     

    ◎ The MH1800 has been designed with all ergonomic considerations in mind. All the components are processed with computer controlled numerical machining centers

    ◎     The specimen retraction function, protects the specimen from blade damage.

    ◎     Electronic Trim/Cut function makes it easy to switch from trim and section mode

    ◎     The MH1800 is equipped with a rotation counter function in order to calculate total section pieces and total thickness.

    ◎     The refrigeration system contains one compressor, which is made in , and freezes the cryostat chamber and shelf separate with environmentally safe refrigerant (R404)

    ◎     The chamber temperature can drop to working condition within 60 minutes after switching the unit on.

    ◎     Sterilization can be accomplished with UV light within 35 minutes after use. 

    ◎     Peltier may be switched on or off manually.

    ◎     Unit contains heated, removable sliding window.

    ◎     Unit contains two defrost methods: definite time and manual

    ◎     The high-precision microtome is enclosed outside the cryostat chamber to protect it from thermal expansion and contraction and keep minimum service and maintenance.

    ◎     Self-explanatory symbols for all functions and displays make the unit easy to learn and operate.

    ◎     LED screen can display data such as sample travel, thickness, function control, day, time, temperature and time on/off.

    ◎     Stand by mode, after initialization, the temperature in cryostat chamber can be controlled between -4℃ an -9℃ by computer automatically; once stopped initializing, the temperature in freeze chamber will arrive to working temperature within 10 minutes

    ◎     Control panel with locking function to avoid improper operation.

    ◎     Multi position handwheel lock.

    ◎     Sensor self-diagnosis function.

    ◎     Wide freezing shelf may put 10 specimen cassettes

    ◎     Specimen orientation on X/Y axes 8°and specimen rotation on Z axes 360°

     

    Technical Specifications

    ◎Freeze chamber temperature rage:-10℃~-30℃

    ◎Cooling down time to -30℃:60 min

    ◎Freeze shelf minimum temperature:-45℃

    ◎Lowest temperature of Peltier unit on freeze shelf:-55℃

    ◎Peltier working time: 15 minutes

    ◎Maximum specimen size:35mm×35mm

    ◎Specimen vertical stroke:60mm

    ◎Specimen horizontal stroke:20mm

    ◎Coarse feeding speed: 0.7mm/s; 0.35mm/s

    ◎Section thickness range: 1μm~80μm adjustable;  1μm~20μm, in 1μm increment

                                                 20μm~40μm, in 2μm increments;  40μm~80μm, in 5μm increments

    ◎Trimming thickness range:10μm~400μm adjustable; 10μm~50μm, in 5μm increments;
                                                         50μm~100μm, in 10μm increments;
                                                        100μm~400μm, in 50μm increments;

    ◎Retraction range: 0μm~80μm adjustable; in 5μm increment

    ◎Voltage and frequency:AC220V±10%   50Hz(Standard) Special requirement may customize by order.
    ◎Power:650W

    ◎Weight:125kg

    ◎Dimensions(W×D×H):660×640×1130mm

     

    【Nothing】 【Next
    Add: No. 5 Hepanxiang, Jinhua, Zhejiang 321001 China      E-mail: info@mossinstruments.com